HeliFlow 412
Positive Displacement Blowers & Vacuum Pumps
Category:
Positive Displacement Blowers & Vacuum Pumps >
HeliFlow
Manufacturer: Gardner Denver
Model Numbers
Latest Revision: A Series
Model | Catalog Number |
---|---|
HYCHMDA | HF 412 LHBD |
HYCHLDA | HF 412 LHTD |
HYCHKDA | HF 412 RHTD |
HYCHJDA | HF 412 RHBD |
HYCHHDA | HF 412 THLD |
HYCHGDA | HF 412 THRD |
HYCHFDA | HF 412 BHLD |
HYCHEDA | HF 412 BHRD |
Previous Revisions
N/A
Timing & Configuration
Units are discharged timed and can be turned in only one direction.
Documentation
Brochures
Performance Curves
Operating & Service Manuals
See Operating & Service Manual for lubrication estimates. Proper oil level is ½ way up the sight glass while the unit is not running.
The latest Operating & Service Manual is on this page; for previous manuals please contact C. Emery Nelson, Inc.
Operating Specifications
Max. RPM: | 4500 |
Min. RPM Vertical: | 900 |
Min. RPM Horizontal: | 900 |
Max. Pressure: | 15 PSI |
Max. Vacuum: | 16 IN HG |
Max. Temp. Rise: | 250°F |
Max. Discharge Temp.: | 350°F |