Sutorbilt 4800 Series 723
Positive Displacement Blowers & Vacuum Pumps
Category:
Positive Displacement Blowers & Vacuum Pumps >
Sutorbilt 4800
Manufacturer: Gardner Denver
Model Numbers
Latest Revision: A Series
Model | Catalog Number |
---|---|
GKGADCA | 723 H-RH-C |
GKGACCA | 723 H-LH-C |
GKGABCA | 723 V-BH-C |
GKGAACA | 723 V-TH-C |
Previous Revisions
N/A
Timing & Configuration
Units are centrally timed but can only be converted to from VT to HL and VB to HR or vice versa as shown below.
Documentation
Brochures
No brochure available.
Performance Curves
Operating & Service Manuals
Drawings
Please contact C. Emery Nelson for drawings: customerservice@cemerynelson.com
See Operating & Service Manual for lubrication estimates. Proper oil level is ½ way up the sight glass while the unit is not running.
The latest Operating & Service Manual is on this page; for previous manuals please contact C. Emery Nelson, Inc.
Operating Specifications
Max. RPM: | 2600 |
Min. RPM Vertical: | 818 |
Min. RPM Horizontal: | 545 |
Max. Pressure: | 12 PSI |
Max. Vacuum: | 16 IN HG |
Max. Temp. Rise: | 250°F |
Max. Discharge Temp.: | 350°F |