Sutorbilt Legend 6LS Positive Displacement Blower/Vacuum Pump

Replaces the 615 URAI/RAI Howden/Roots and Competitor Plus 6015 from Tuthill

In stock

Model Numbers

Latest Revision: S Series
Model Catalog Number
GAFLDSA 6LS-RHC
GAFLCSA 6LS-LHC
GAFLBSA 6LVS-BHC
GAFLASA 6LVS-THC
Previous Revision: R Series
Model Catalog Number
GAFLDRA 6LR-RHC
GAFLCRA 6LR-LHC
GAFLBRA 6LVR-BHC
GAFLARA 6LVR-THC

Not listed: P, L, F and B Series

Standard models are centrally timed with Universal Foot for (4) shaft locations (see below).

Documentation

Operating & Service Manuals

See Operating & Service Manual for lubrication estimates. Proper oil level is ½ way up the sight glass while the unit is not running.

The latest Operating & Service Manual is on this page; for previous manuals please contact C. Emery Nelson, Inc.

Operating Specifications

Max. RPM: 2350
Min. RPM Vertical: 891
Min. RPM Horizontal: 637
Max. Pressure: 7 PSI
Max. Vacuum: 14 IN HG
Max. Temp. Rise: 160°F
Max. Discharge Temp.: 260°F